Sign In | Join Free | My himfr.com
Home > Lithium Battery Testing Equipment >

100V 100A Lithium Battery Testing Equipment Charge Discharge Model

Dongguan Kingpo Technology Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 100V 100A Lithium Battery Testing Equipment Charge Discharge Model from wholesalers
     
    Buy cheap 100V 100A Lithium Battery Testing Equipment Charge Discharge Model from wholesalers
    • Buy cheap 100V 100A Lithium Battery Testing Equipment Charge Discharge Model from wholesalers

    100V 100A Lithium Battery Testing Equipment Charge Discharge Model

    Ask Lasest Price
    Brand Name : KingPo
    Certification : ISO 17025 Calibration certificate
    Price : To be quoted
    Delivery Time : 25~30 working days
    Payment Terms : 100% TT in advance
    Supply Ability : 3~5 units per month
    • Product Details
    • Company Profile

    100V 100A Lithium Battery Testing Equipment Charge Discharge Model

    100V100A Charge And Discharge Battery Testing Machine


    100V 100A Lithium Battery Testing Equipment Charge Discharge Model


    Product Details


    Application Scope and Function of Equipment

    1.1Scope of equipment application: Mainly used to include lithium ion batteries, lead acid batteries, nickel cadmium batteries, nickel hydrogen batteries and other batteries in the production or experiment (CircleLifeTesting) and quality control.

    1.2test contents of the support: battery cycle life test, battery capacity test, battery charging characteristics test, battery discharge characteristics test, battery charge-holding capacity test, battery charge-discharge efficiency test, battery overcharge, over-discharge rate tolerance test, etc.

    Equipment environmental requirements and technical parameters

    Power supply: AC voltage 380V ±10%, frequency:50Hz ±10%

    Ambient temperature:0-45°C

    Environmental humidity: not greater than 95% R.H (anhydrous vapor condensation)

    No strong vibrations, non-corrosive gases and inflammable and explosive gases

    Resolution: AD:16bit

    Technical parameters


    Number

    Model

    RCDS-100V100A

    1

    Number of Main Channels

    4CH / Rack

    2

    output power

    Maximum power 10kW for channel operation; no time limit

    3

    output power stability

    ±(0.1%FS+0.1%RD)

    4

    Input side power quality

    power factor

    >99%loaded to capacity

    Total harmonic distortion rate

    ≤5%loaded to capacity

    6

    Energy consumption parameters

    Standard sine wave feedback energy, high efficiency (optimum efficiency 90%)

    7

    Main Channel Working Mode

    Charging: constant current charging CC, constant voltage charging CV, constant current constant voltage charging CCCV, constant current constant voltage charging process conversion needs to achieve no impulse voltage current;

    Discharge: constant current discharge CD, constant power amplifier CP, constant resistance discharge CR, constant voltage constant current discharge

    pause n.

    Keywords Working condition test; Pulse test;

    8

    Main channel voltage

    Single Channel Measurement Range

    0.2V-100V, with continuously adjustable intermediate values (wide test range, suitable for various battery module test requirements)

    Minimum discharge voltage

    7V

    precision

    ±(0.05%FS+0.05%RD)

    Resolution

    1mV

    Main channel current

    Single Channel Measurement Range

    -200A~+200A

    Minimum output current

    150mA

    precision

    ±(0.05%FS+0.05%RD)

    resolution ratio

    1mA

    response time

    <10ms

    apolegamy assist

    voltage

    Number of channels

    32

    Measurement range

    DC:0-5V

    Measurement precision

    ±(0.05%FS+0.05%RD)

    resolution ratio

    1mV

    apolegamy assist

    temperature

    number of tracks

    8

    Measuring Range

    ﹣50℃~300℃

    Accuracy in measurement

    ±1℃

    Resolution ratio

    0.1℃

    time

    Data acquisition resolution

    10ms

    9

    Equipment communication mode

    Support LAN communications

    Battery BMS communications

    Support CAN 2.0A, CAN 2.0B; RS485 communications

    Supports DBC import, enables data reading with BMS CAN and participates in process control

    10

    Control control program

    Support power down data protection, support for power failure, manual stop, data file succession testing, online modification of step parameters

    Safety protection conditions can be set. Parameters include: voltage lower limit, voltage upper limit, current lower limit, current upper limit temperature upper limit

    Auxiliary channel / BMS protection conditions can be set. The parameters can include: voltage upper limit, voltage lower limit, temperature upper limit, temperature lower limit, single cell pressure difference

    cycle index

    MAX10000

    Programmable steps

    MAX10000

    Loop nesting

    Maximum 10 floors

    Step Time Range

    Unlimited support for h, min, s format

    Minimum interval for data recording

    Time ≥10ms, voltage ≥0.1% FS, current ≥0.1% FS, and supporting step-by-step setting of recording conditions

    Programming Features

    Each work step may have one or more exits

    11

    work pattern

    Constant-current charging

    Battery pack voltage, time, capacity, electricity, monomer temperature, monomer voltage, cell voltage difference, RSOC,- V up to

    Constant-voltage charging

    Current, time, capacity, electricity, monomer temperature, monomer voltage, cell voltage difference, RSOC,- V up to

    Constant current and constant voltage charging

    Current, time, capacity, electricity, monomer temperature, monomer voltage, cell voltage difference, RSOC,- V up to

    Shelve

    End of time

    Constant-current discharge

    Battery pack voltage, time, capacity, electricity, cell temperature, cell voltage, cell voltage difference up to

    Constant power discharge

    Battery pack voltage, current, time, capacity, electricity, cell temperature, cell voltage, cell voltage difference up to

    Constant resistance discharge

    Battery pack voltage, current, time, capacity, electricity, cell temperature, cell voltage, cell voltage difference up to

    12

    Data presentation

    Circular list

    Have cycle serial number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge level average voltage, etc.

    List of processes

    There are process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc.

    Detailed list

    There are record number, system time, accumulative time, voltage, current, energy, monomer temperature1--monomer temperature n, monomer voltage 1-- monomer voltage n, monomer voltage extreme difference, etc.

    13

    Data export

    Data can be led into excel, TXT, chart file, can provide charge-discharge curve, capacity decay rate, cycle life curve, charge-discharge voltage, current, capacity-time and other ways of data analysis curve and data list

    14

    Data save mode

    The user can customize the name and the data save path, and the data can be saved by file

    15

    Type of curve

    X coordinates: total time, charge/discharge time/capacity, number of cycles

    Y coordinates: total voltage, current, capacity, energy, monomer voltage 1-monomer voltage n, monomer temperature 1-monomer temperature n

    16

    Input protection

    Over-voltage, over-current, lack of phase, over-temperature, protection alarm;

    Output protection

    Over-voltage, over-current, short-circuit, capacity, temperature, monomer overvoltage, monomer under-voltage protection; without detecting the battery voltage, no output;

    Power-off protection

    After the external power is cut off, the battery and the equipment are automatically disconnected to avoid the accident caused by re-powering.

    Hardware protection

    Power off protection, open circuit protection, short circuit protection; battery connection back, fault protection, over-current protection, overvoltage protection, over-temperature protection, hardware overvoltage over-current protection

    Short-circuit protection

    External short circuit;

    Software protection

    Power down data protection, call continuation, overvoltage over-discharge protection, over-current protection, capacity protection, over-temperature protection, voltage trend abnormal protection, current trend abnormal protection, current fluctuation abnormal protection, voltage fluctuation abnormal protection, charge voltage rise speed abnormal protection, discharge current drop speed abnormal protection, equipment communication abnormal protection, auxiliary module communication abnormal protection

    Alarm function

    The hardware has the functions of emergency cutting off switch, automatic shutdown after power off, automatic load connection and disconnection.

    17

    Cooling-down method

    Forced air cooling

    18

    Sampling terminals

    Four-electrode sampling mode, fixture line terminal or other

    19

    Auxiliary Channel Collection Line

    Acquisition cable length adjustable according to actual situation

    20

    Security classification

    Meet EN 60950, GB 4943 requirements

    noise

    The noise is less than 70dBA, the sound level meter used should meet the requirements of type I in IEC804, and the accuracy should be better than ±0.5dB.

    Levels of protection

    IP20

    Lightning protection

    Level 2 lightning protection requirements for GB 17626

    21

    Maintainability

    Modular structure, spare parts available for timely replacement, maintenance, free of charge during the warranty period

    22

    Software upgrade service

    Software upgrade service provided until hardware is incompatible


    Optional thermostat control function

    The software supports extended function software, which can automatically control the thermostat to start and stop, and adjust the temperature and humidity

    Device specific advantages

    Energy feedback (standard sine wave feedback energy, best efficiency 90%): energy feedback type, charge and discharge two-way are energy-saving, can save a lot of electricity consumption, while saving a lot of energy energy generated by the cost of air conditioning electricity.

    CCCV charging: charging process CCCV no gap transition, no any voltage current impact. It can effectively prevent the protection action and the secondary protection action of PCB caused by the peak current of the battery due to the heat concentration of the polar ear depowdering or the micro-short circuit producing the island effect or the overshoot phenomenon.

    The current and voltage sampling stability is good and the precision is high: high precision, high dynamic range ADC/DAC unit, high voltage sampling accuracy and good long-term stability.

    IDUser management consists of three parts: permission management, role management and user management. The administrator can set administrative permissions for each functional module of the software, and set multiple user IDs according to the permissions of the operator

    DL Dynamic Load Protection Function: Effectively protects the battery in the charge and discharge, prevents the battery fire and effectively avoids the current shock caused by the loosening of the connector, and effectively protects the electronic components of the battery from being damaged by the shock current, such as MOSFET, FUSE

    Voltage clamp function: During the charging process in the battery protection action or equipment abnormal, the voltage clamp position in the safe voltage to prevent battery or battery pack protection plate damage.

    The test step can set the record condition in sections and implement the intelligent data management record.

    Support BMS CAN communication function: real-time acquisition of BMS system total voltage, total current, single core voltage, temperature and other data, and CDS voltage and current data to do synchronous comparison, set BMS voltage and current temperature and other data to meet certain conditions, the main channel steps to stop or convert, specific reading information provided by the customer related information.

    A custom set of signals is supported. The user can customize the name according to their own requirements and data records. By adding "sub-signal quantity" as the protection parameter, the protection

    Parameter can be set multiple, and the result can generate a new decision condition by calculating the operator "maximum value, minimum value, difference value, mean value,-,×," function relation

    Charge And Discharge Battery Testing Machine Minimum Output Current 150mA 0

    File query: can be based on the test date, test channels, keywords and other information search related, and support data batch export

    Charge And Discharge Battery Testing Machine Minimum Output Current 150mA 1

    Appearance and Structure of Equipment

    Cabinet


    Rack size (W*D*H)

    600*800*1980mm

    weight

    ≤300kg

    Number of modules

    4CH / Rack

    Remark: The above picture is for reference only, subject to physical object!

    Software Testing InterfaceSoftware Testing InterfaceCharge And Discharge Battery Testing Machine Minimum Output Current 150mA 2Setup interfaceCharge And Discharge Battery Testing Machine Minimum Output Current 150mA 3Data interfaceCharge And Discharge Battery Testing Machine Minimum Output Current 150mA 4Curve alignment interfaceCharge And Discharge Battery Testing Machine Minimum Output Current 150mA 5Working condition simulation setup interfaceCharge And Discharge Battery Testing Machine Minimum Output Current 150mA 6Working condition simulation data interfaceCharge And Discharge Battery Testing Machine Minimum Output Current 150mA 7


    Hot Tags: charge and discharge battery testing machine, China, manufacturers, suppliers, factory, custom, wholesale, Screwless Terminal Voltage Drop Tester, Children Test Finger Probe 18 And 19, Hot Winding Resistance Meter, IEC60255-5 High Voltage Impulse Generator, UL 60335-2-24 Figure 101.DVA.1 Articulate Finger, IEC61032 Test Probe B With Force

    Quality 100V 100A Lithium Battery Testing Equipment Charge Discharge Model for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Dongguan Kingpo Technology Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)