Sign In | Join Free | My himfr.com
Home > Medical Testing Equipment >

300W Medical Device Testing Equipment for Particle Protection Effect

Dongguan Kingpo Technology Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 300W Medical Device Testing Equipment for Particle Protection Effect from wholesalers
     
    Buy cheap 300W Medical Device Testing Equipment for Particle Protection Effect from wholesalers
    • Buy cheap 300W Medical Device Testing Equipment for Particle Protection Effect from wholesalers

    300W Medical Device Testing Equipment for Particle Protection Effect

    Ask Lasest Price
    Brand Name : KINGPO
    Certification : calibration certificates
    Price : To be quoted
    Payment Terms : T/T
    Supply Ability : 3 sets per month
    Delivery Time : 30 working days
    • Product Details
    • Company Profile

    300W Medical Device Testing Equipment for Particle Protection Effect

    300W Medical Device Testing Equipment For Particle Protection Effect

    Respirator Particle Protection Effect Tester


    1 Product introduction

    ZR - 1002 masks particle detector is protective effect on volume of 500 l self-purification test chamber was gb head mould, will be waiting for inspection masks worn on the head, by any quality median diameter was (0.6 + / - 0.050 mu m, in the salt concentration of 20 mg/m3 aerosols and mass median diameter was (0.3 + 0.050) microns, concentration of 20 mg/m3 of oily aerosol net input from the test chamber, head do sine curve simulation breath, before using the photometer upstream and downstream sampling detection mask and mask after salt aerosols and oily aerosol concentration,To evaluate the protection effect of respirator particles.The mask can be worn on the national head mold to automatically detect respiratory resistance.It is applicable to the detection of the protective effect of respirator, filter material and other particulate matter by medical instrument inspection institute, center for disease control and prevention, hospital, hepa filter manufacturer, mask r&d and manufacturer.


    2 Scope of application

    It is applicable to the detection of the protective effect of respirator, filter material and other particulate matter by medical instrument inspection institute, center for disease control and prevention, hospital, hepa filter manufacturer, mask r&d and manufacturer.


    3 Sampling standard

    GB/T6165-2008 Performance test methods for hepa filters - technical requirements and test methods for efficiency and resistance of particulate matter protection

    GB2626-2019 Respiratory protective self-absorption filter respirator against particulate matter

    GB/T 32610-2016 Technical requirements for daily protective masks


    4 Main features

     Respirator particle protection and respiratory resistance detection integrated design, one machine multi-purpose

     The self-cleaning test chamber is equipped with operation gloves to facilitate the replacement of the inspection mask.

     Three kinds of head - mode compatibility design, head - mode plug and play, convenient replacement.

     The salt and oil aerosol generator can be used to control the concentration of particulate matter.

     The large touch display is designed to automatically display the respiratory flow curve and automatically calculate the protection effect of particulate matter.

     The whole process of particle leakage prevention design, to protect the safety of the experimenters.

     Photometer long life laser light source, high precision photomultiplier detection.

     Photometer working time statistics, automatic indication of cleaning time.

     The use time of hepa filter is automatically counted, which prompts the replacement of hepa filter.

     Historical data can be exported via a U disk or printed via an embedded printer.


    5 Technical indicators

    Calibration of the main technical indicators of the device.

    main parameters parameters resolution Maximum permissible error

    Concentration detection sampling flow 1L/min 0.01L/min ±2.5%

    Concentration detection range (0.001~100)μg/L

    precision 1%

    Median mass diameter of salt aerosol (0.6±0.05)μm

    Median mass diameter of oil aerosol (0.3±0.05)μm

    Simulated respiration curve Sine curve

    Breathing rate 20 times/min

    Breathing moisture 1.5L

    Self cleaning volume 500L

    Since the net time (1~5)min

    Respiratory resistance measures flow 85L/min 0.1L/min ±2.5%

    Respiratory resistance detection range (0~1500)Pa 1Pa ±1%

    Power AC220V 50/60Hz

    Size of the host (length1350×wide800×high1840)mm

    Power consumption of the host <300W

    Host weight About200kg





    Quality 300W Medical Device Testing Equipment for Particle Protection Effect for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Dongguan Kingpo Technology Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)